PDF | 7.7MB
From an aesthetic viewpoint, SimpleLine® has strong, clean edges that provide for an express panel look without the cost.
A simple blank canvas primed and ready for a final paint finish, these panels have ship-lapped vertical edges that are suitable for gun-nailing for fast installation. There are multiple installation methods to give you choice and flexibility.
Features
- Strong, clean edges that provide for an express panel look without the cost
- Simple blank canvas, primed and ready for a final paint finish
- Ship-lapped vertical edges are suitable for gun-nailing for fast installation
- Multiple installation methods give you choice and flexibility
Downloads
Associated files for this Cemintel product are available for download.
Modern Cladding Product Flyer
SimpleLine BIM files
ZIP | 903.5KB
SimpleLine Product Warranty
PDF | 102.6KB
Air Barriers Design & Installation Guide
PDF | 10.2MB
Cemintel Product Portfolio
PDF | 16.0MB
Fire Performance Guide - Fibre Cement Cladding
PDF | 3.3MB
Fibre Cement Safety Data Sheet
PDF | 715.8KB
Technical Data
APPLICATIONS
| Result | |
|---|---|
| Applications | Façades & Cladding, Internal Linings |
| Type of Building Structure | Residential Housing Buildings within the scope of AS4055 |
| Wet Areas | No |
PANEL - DIMENSIONAL & GEOMETRICAL CHARACTERISTICS
| Dimensional/Geometrical Characteristic | Specification | Manufacturing Tolerance | Relevant Standard |
|---|---|---|---|
| Panel Dimensions | 900mmW x 3000mmL x 8.5mmD 1200mmW x 2400mmL x 8.5mmD 1200mmW x 3000mm L x 8.5mmD |
Width +0 -1 mm Length +0 -3 mm Thickness +0.3 -0 mm |
|
| Profile | Shiplap | ||
| Perpendicularity/squareness of edges | 1mm/linear meter | ||
| Weight (typical) | 13.3kg/m2 | ||
| Layout Options | Vertical | ||
| Jointing | Concealed |
PANEL - STRENGTH & MOISTURE RELATED PROPERTIES
| Physical Property | Result | Relevant Standard |
|---|---|---|
| Modulus of Rupture (Wet) | > 9 MPa | AS2908.2 |
| Modulus of Elasticity (Wet) | 3-5 GPa | AS2908.2 |
| Density (Oven Dry) | 1280 kg/m3 | AS2908.2 |
| Water Vapor Diffusion | Not Required | Not Required |
| Water Tightness (24hrs) | No water droplet | AS2908.2 |
| Water Absorption (Saturated – 48hrs) | 30 wt% | ASTM C 1186 |
| Moisture Content (EMC) | 7 wt% | ASTM C 1186 |
| Moisture Movement | 0.05% | ASTM C 1186 |
PANEL - OTHER DURABILITY/WEATHER RESISTANCE INDICATORS
| Test | Result | Relevant Standard |
|---|---|---|
| Heat Rain | PASSED (25 Cycles) | AS2908.2 |
| Freeze Thaw | PASSED (50 Cycles) | AS2908.2 |
| Warm Water Resistance | PASSED (56 days) | AS2908.2 |
| Soak Dry | PASSED (25 Cycles) | AS2908.2 |
PANEL - FINISH CHARACTERISTICS
| Characteristic | Result | Relevant Standard |
|---|---|---|
| Finish | Preprimed | |
| Coating Type | Sealer Type: Pigmented Sealer On Face | |
| Colour Bodied | No | |
| Paint Type | ||
| UV Resistance | N/A | N/A |
| Formaldehyde Emission Rate | N/A | N/A |
| VOC Emission Rate | N/A | N/A |
| Spectral Reflectivity Values | Solar Reflectance % | Solar Absorption % | Basix Colour | Relevant Standard |
|---|---|---|---|---|
| SimpleLine® | N/A |
PANEL - FIRE RESISTANCE, THERMAL & ACCOUSTIC PROPERTIES
| Characteristic | Result | Relevant Standard |
|---|---|---|
| FIRE RESISTANCE | ||
| Combustibility | N/A | |
| Fire Hazard Properties | N/A | N/A |
| Classification | N/A | N/A |
| Surface Burning Characteristics | AS1530.3 | |
| THERMAL CONDUCTIVITY | ||
| Thermal Conductivity (λ-Factor) | ≈ 0.2835 W/m.K | |
| Thermal Expansion Co-efficient | 0.005-0.01mm/mK | N/A |
| ACOUSTIC VALUE | ||
| Sound reduction (depends on construction) | N/A | N/A |
SYSTEM SOLUTIONS
| Characteristic | Result | Relevant Standard |
|---|---|---|
| Within Scope of AS4055? | Yes | |
| Wind Loading - Residential housing buildings within the scope of AS4055 | N1, N2, N3, N4, N5, N6, C1, C2, C3, C4 | |
| Weatherproofing | Suitable for all building classes as set out in the BCA (ie 1&10,2-9) | N/A |
| Cyclonic Conditions | N/A | N/A |
| Fire Resistance Limits (FRLs) | Up to 60/60/60 90/90/90 | Refer to Gyprock® The Red Book™ |
| Bushfire Construction | BAL 29 (Construction for Bushfire Attack Level 29 for an external wall) | AS 3959-8 |
| Acoustic | Acoustic solutions of up to RW/RW+CTR 49/39 are detailed | Refer to Gyprock® The Red Book™ |
| Thermal | Thermal solutions of up to RT(sum)/RT(win) 3.4/3.8 | Refer to Gyprock® The Red Book™ |
FIXING
| Characteristic | |
|---|---|
| Maximum Span (Stud Spacing) | Up to 600mm |
| DIRECT FIX | |
| Nail to Timber Frame | Yes |
| Screw to Timber Frame | No |
| Screw to Steel Frame | Yes |
| INDIRECT FIX | |
| Timber Frame | Yes |
| Steel Frame | No |
| Masonry Frame | No |
| EXPOSED FASTENERS | |
| Screw | Yes |
| Rivet | No |
| Nail | Yes |
| CONCEALED FASTENERS | |
| Clip | No |
| Countersunk Screw/Nail | No |
| Adhesive, Split Batten, etc. | No |
| Hidden by Overlapping Panel | No |
| Flush Jointed (Taped) | No |
WARRANTY 10 Years
Other Recommended Products
You may also be interested in these Cemintel products to work with, complement, or as an alternative to the product you are currently viewing.